Measurements of flow rates for solid materials
Bulk Flow Meter LB 472
The LB 472 DuoSeries Bulk Flow System is a Radiometric Belt Scale, measuring production throughput or mass flow in e.g. t/h. It is mainly used for bulk materials (powders, granulates or chunks). The LB 472 is based on the proven 2-wire technology, succeeding the LB 442 Bulk Flow Meter. The transmitter is operated in combination with LB 4700 Detectors.
User interfaces:
- Operating Languages: English, German, Chinese, French, Italian, Portuguese, Russian, Korean, Spanish, Finish, Romanian, Serbian, Bulgarian
- 3,5“ LC color touch display (320x240 pixels)
- USB mouse / keyboard support
- On-screen keyboard
- Ethernet remote control
Power supply:
- Wide range 100 ... 240 V AC
- 24 V DC
Environmental conditions:
- Operating temperature: -20°C ... +50°C
Inputs and outputs:
- LB 4700 detector interface (Fully compatible to the LB 44xx / 54xx detectors)
- Master / slave interface
- RS-485
- USB & ethernet ports
- Monitored current output (4-20 mA) with user-defined mapping
- 1 Error-relay (SPDT)
- 2 Alarm relays (1x SPDT & 1x SPST) with user-defined mapping
- 2 Digital inputs with user-defined mapping
Diagnostic functionality:
- Self-diagnostics according to Namur NE-107
- Event log
- Event counter
- Change log
- Data log
Software features:
- Linear, square and cubic calibration
- Calibration schemes:
- Comparative weighing
- Static
- Average Mass per unit area
- Direct
- Calibration adjust
- Process value and detector temperature alarms
- Radiation interference detection
- Source replacement notification
- Simulation mode for all relevant measurement values
Competitive arguments for LB472:
- The technology of radiometric belt scale is superior over conventional weighing technologies
- Berthold product offers better long term stability
- Only point source arrangement available, however best accuracy and performance is achieved with Co-60 rod source.
- Temperature variations or other environmental factors have no influence to measurement.
- Low activity of radiation source – by using high sensitivity detectors.
- 2 wire technology make possible simultaneous transmission for data and power voltage. By using FSK modulation for data transmission the system has immunity to external interferences.